UPS System Oregon

- RESILIENT & SCALABLE

Communications Site UPS

Hybrid Power System

Rack-integrated UPS hybrid power system with energy storage, grid power, backup generator management, renewable energy inputs and power conversion.

 

Designed to ensure critical communication systems never go without power, this solution is highly configurable and scalable to meet mission needs at any site.

 

Available in Small, Medium, and Large stack configurations to match backup duration to site criticality, including single-stack remote radio sites to four-stack configurations protecting critical infrastructure.

POWER

Up to 20 kW

CAPACITY

Up to 273 kWh

RATING

0.99 Power Factor

- APPLICATIONS

Where Communications Site UPS gets deployed

Keeps critical links up when the grid, the generator, or the controller itself falters.

  • Remote & Unmanned Sites

    Runs unattended for extended periods, with remote monitoring standing in for a technician on-site.

  • Grid-Generator Transition Points

    Rides through grid-to-generator and generator-to-grid switching with zero drop-out, protecting sensitive DC loads.

  • Extended Outage Protection

    Automatically shifts into hybrid mode to stretch generator runtime and fuel during prolonged outages.

  • Redundancy For Critical Infrastructure

    Keeps delivering full load even if the system controller itself fails, a level of resilience most UPS systems can't claim.

- PRODUCT SPECIFICATIONS

Communications Site UPS technical data

Size Model Configuration Battery Storage Battery Quantity Number of Racks Datasheet
Small
SBPS-0088-C12-SOL-00
1-stack
38.4 kWh
12
3
Medium
SBPS-0176-C24-SOL-00
2-stack
76.8 kWh
24
5
Large
SBPS-0176-C48-SOL-00
4-stack
153.6 kWh
48
9

- Supporting Products

Hybrid System Controller

The ZeroBase® Hybrid System Controller provides an integrated platform to manage and optimize hybrid energy systems across mobile and stationary applications.

The controller centrally manages power conversion, generation, and energy storage, with programmable controls that optimize power use, intelligently cycle generators, maintain configurable battery reserves, and monitor system health. Extensive fault monitoring, data logging, communications, and device integration support early issue detection, real-time mitigation, and system protection.

The companion ZeroBase® Human Machine Interface (HMI) provides operators with intuitive access to real-time system status, component data, historical performance, and configurable settings. Together with EMPAC-T, the solution provides flexible, intelligent management of hybrid power operations while maintaining system resilience.

- WHY COMMUNICATIONS SITE UPS

Reliable backup power for demanding applications

Grid-Present Charging

Batteries stay fully charged whenever grid power is present for instant UPS readiness, and the system can also accept lower-power generators as an emergency backup option.

Zero Drop-Out DC Bus

Low-impedance, direct-from-battery DC bus delivers clean power through failures and grid-generator transitions with no interruption.

Controller-Independent Resilience

Maintains full power output even in the event of total system controller loss, a fail-safe most UPS designs don't offer.

Intelligent Hybrid Operation

Automatic hybrid power mode reduces generator runtime and fuel consumption during extended outages, and interacts with existing ATS systems with minimal modification.

Continuous Fault Monitoring

Every component is continually monitored for faults or degraded performance, with loads automatically redistributed if an issue is detected.

Remote Visibility

HMI allows remote access and monitoring via the internet, with full data logging of components, warnings, and faults.