Introduction

Power outages are no longer an occasional disruption that organizations can simply work around. For critical public-sector facilities, an extended loss of electricity can affect emergency response, essential services, communications, safety and the ability to maintain operations. 

And the risk is increasing. According to the U.S. Energy Information Administration, U.S. electricity customers averaged nearly 11 hours without power in 2024, almost twice the previous decade’s average.  

Major storms, including Hurricanes Beryl, Helene and Milton, accounted for approximately 80% of those outage hours. Hurricane Helene alone disrupted service for 5.9 million customers across 10 states, while customers in South Carolina experienced an average of nearly 53 hours of interruptions during the year. 

For organizations responsible for critical infrastructure, the question is not whether an outage will occur, but whether operations can continue when it does. That depends on having a business continuity plan that addresses power disruption and, equally important, testing that plan before an emergency occurs. 

This guide outlines six steps for developing a business continuity plan for power-outage scenarios, with practical considerations for emergency management organizations, public works departments, school systems, utilities, and other organizations responsible for maintaining essential services. 

Key Takeaways

Why Power Loss Deserves Its Own Continuity Plan

A comprehensive business continuity plan should treat power resilience as a critical operational requirement, not simply one item within a broader list of potential disruptions. A prolonged power outage can quickly affect the interconnected systems organizations rely on to maintain essential services: 

  • IT and data: Servers, network infrastructure, dispatch platforms, SCADA systems and other mission-critical applications may be unavailable without reliable power. 
  • Communications: Radio repeaters, phone systems, cellular boosters and public alerting infrastructure may be disrupted, limiting an organization’s ability to communicate internally and with the public. 
  • HVAC: Heating and cooling systems may be essential for maintaining safe conditions in shelters, server rooms, healthcare environments and other critical facilities. 
  • Refrigeration: Extended outages can put vaccines, food supplies, laboratory samples and other temperature-sensitive materials at risk. 
  • Security: Access-control systems, surveillance cameras and fire alarm panels may have limited operating capacity when backup batteries are depleted. 
  • Water and wastewater: Lift stations, booster pumps and treatment processes may require continuous power to maintain service and prevent secondary failures. 

Organizations should also account for the potential duration of an outage. Utility restoration is not always immediate, even when utilities have invested significantly in grid hardening and resilience.  

Restoration crews may need to inspect transmission and distribution infrastructure, clear debris, repair damaged equipment and safely re-energize circuits. Flooding and other severe weather can further extend recovery timelines, particularly when substations or other critical infrastructure require inspection, drying, or reconstruction before returning to service. 

Federal guidance reinforces the need to plan for extended disruptions. CISA’s Resilient Power Best Practices for Critical Facilities and Sites identifies fuel reserves ranging from approximately three days at one resilience level to approximately 30 days at level three resilience.  

For business continuity planning, three to seven days is therefore a useful baseline for assessing an organization’s ability to operate without utility power. The planning process should work backward from that scenario: identify which operations must remain available, determine the systems and infrastructure required to support them, and establish the backup power, fuel, personnel and procedures necessary to sustain those operations. 

Step 1 — Conduct a Business Impact Analysis

A business impact analysis (BIA) tells you what an outage would cost before you spend anything to prevent it. Ready.gov describes it as the process that predicts the consequences of a disruption and gathers the information needed to develop recovery strategies. 

Start with a BIA questionnaire. Send it to the managers and operators who know how each service is delivered in detail, because they know which processes fail first and which workarounds exist. For a power-focused BIA, ask each of them: 

  • Which processes stop immediately when power is lost, and which degrade over hours? 
  • What resources does each process need to run at full, reduced and minimum levels? 
  • How long can the process be down before the consequences become unacceptable? 
  • What does an hour, a day and a week of downtime cost? 

The answers should identify your critical processes and the resources each one needs to function at different levels. That last part matters for power planning. A water plant running at minimum safe output draws far less than the same plant at full production. 

Then put numbers on it. Ready.gov advises assessing significant interruption scenarios in financial terms where possible and comparing those costs with the cost of recovery strategies.  

For public agencies, cost includes more than revenue: overtime, spoiled inventory, regulatory penalties, emergency contracting, and the harder-to-price cost of a missed 911 call or a boil-water notice. This comparison is what justifies the backup power budget later. 

Step 2 — Identify and Prioritize Critical Loads

The BIA ranks processes. This step translates that ranking into electrical loads, sorted into three tiers. 

Tier What Belongs Here During an Outage
Must-run
Life safety systems, communications, IT, refrigeration, pumps
Powered continuously
Important but flexible
Comfort HVAC, office equipment, general lighting
Powered on a schedule or when capacity allows
Sheddable
Decorative lighting, EV charging, break-room appliances, non-essential plug loads
Switched off first

Next, write a load-shedding sequence. Decide in advance which loads drop at the start of an outage, which drop after 24 hours, and which drop only if fuel or battery reserves fall below a set threshold. Every kilowatt you shed extends the runtime of whatever backup power you have. 

Then size the loads in kilowatts. Record the running load for each tier and the starting surge for motors such as pumps and compressors. This figure drives equipment selection in Step 4, so measure it with metering data or a load study, not nameplate estimates. 

Keep the utility side in view as well. Utilities generally restore hospitals, police, fire and wastewater facilities first. Schools, public works yards, administrative buildings and most private businesses sit lower on the list and can wait much longer. If your facility is not at the top of the restoration order, on-site power is the only control you have over your own timeline. 

Step 3 — Set Recovery Objectives (RTO and RPO)

Two numbers turn priorities into engineering requirements. 

  • Recovery Time Objective (RTO): the longest a process can stay down before the consequences become unacceptable. 
  • Recovery Point Objective (RPO): the most data, measured in time, that you can afford to lose when a system goes down. 

Per Ready.gov, recovery strategies are alternative ways to restore operations to a minimum acceptable level, prioritized by the RTOs set during the BIA. In a power outage, the RTO decides what kind of backup each load needs. An RTO of seconds requires batteries that pick up the load without a gap. An RTO of hours can wait for a generator to be towed in and connected. 

Illustrative targets for a county government might look like this: 

Function Example RTO What It Implies
911 Dispatch & Radio Systems
Seconds
Battery-backed power with no transfer gap
Water & Wastewater Pumping
Minutes
Automatic start and transfer
Emergency Shelter Heating & Cooling
1 to 4 hours
Pre-staged or rapidly deployed power
Administrative Offices
Within 24 hours
Shared or relocated resources

Set RPOs for the data behind those functions too. A dispatch log that loses its last ten minutes during a hard shutdown is a records problem and potentially a legal one. 

Step 4 — Choose a Backup Power Strategy That Fits

With loads sized and RTOs set, you can match equipment to requirements. Four options cover most situations. 

Option Best At Limits
Standby Generator
Long runtime at high output
Needs fuel deliveries; start-up gap; noise and emissions
UPS
Instant, clean power for IT and communications
Minutes to a few hours of runtime
Permanent Microgrid
Whole-facility resilience with solar and storage
High capital cost; serves one site
Mobile Hybrid System
Battery, generator, and solar in one deployable unit
Sized for specific loads, not an entire campus

Many facilities stop at a standby generator. In a short outage, that works. A week-long event exposes the weaknesses: 

  • Fuel delivery: the same flooded or blocked roads that delay utility crews delay fuel trucks. 
  • Continuous runtime: a generator running around the clock at light load burns fuel inefficiently and wears faster. 
  • Noise: constant engine noise is hard on shelter occupants, dispatchers and neighbors. 
  • Maintenance: oil and filter service intervals arrive quickly at 24 hours a day. 
  • Single point of failure: if the one generator fails to start or faults on day three, the facility is dark.

There is also a coverage problem. One fixed system protects one building. Severe weather creates mobile power needs, like a shelter opened at a school, a command post in a parking lot, a distribution point at a fairground, or a lift station whose own generator failed. A business continuity plan for power outage events should include at least some power that can go where the event sends it. 

Flexible Hybrid Power for Severe Weather

Hybrid power systems address most of the generator-only weaknesses above by changing how the generator is used. AGBESS offers ZeroBase® hybrid mobile power systems for agencies that need this capability in a mobile form. 

How a Hybrid Power System Works

The result is a generator that runs for a few hours a day at an efficient load instead of idling around the clock. Fuel lasts longer, service intervals stretch out, and the site is quiet for most of the day. The battery also covers the gap if the generator faults, which removes the single point of failure. 

The EMPAC-T puts this architecture on a trailer. Its power management system controls the generator automatically, limiting it to recharging or supplemental power and significantly cutting fuel use. 

Typical uses include emergency operations centers, mobile command, shelters, points of distribution (PODs) and communications sites. Nassau County, New York’s Office of Emergency Management took delivery of ZeroBase trailers to power command and communication vehicles and POD sites, where clean, quiet operation is preferred. 

When the load is larger than a trailer can carry, the MX Series scales the same approach up. It is a self-contained, environmentally controlled system that can be operational minutes after delivery. It provides up to 120 kW of three-phase power, interfaces with up to two generators or a generator plus the grid, and transitions between modes without interrupting the load. 

That makes it a fit for temporary shelters, operations centers supporting critical IT, and grid stabilization at sites with intermittent power problems.

A controller manages four possible sources: batteries, a generator, solar and the grid. During an outage, the batteries carry most of the normal load. The generator starts only to cover excess demand or to recharge the batteries, then shuts off again until grid power returns. 

Step 5 — Build Communication Protocols

Power equipment keeps systems running. Communication keeps people coordinated, and it often fails in less obvious ways. Email servers go down with the building, desk phones die, and staff at home may have no power or cell coverage either. 

Your plan needs three things in writing. 

  • Internal alerts that do not depend on email. Use SMS or a mass-notification service as the primary channel, with radio as the fallback. Keep a printed call tree in every facility, since a contact list stored on a dead server helps nobody. 
  • External updates. Residents, customers and regulators each need different information on different schedules. Residents want to know which shelters are open and whether water is safe. Regulators want incident notifications in the required format and timeframe. Draft message templates before storm season so the first update goes out in minutes. 
  • Assigned roles. Name who declares the outage response, who briefs elected officials, who speaks to the media, and who updates the website and social channels. Name a backup for each. During a multi-day event, people need to sleep, and the plan should say who takes over. 

Power the communication tools themselves, too. Radio repeaters, cellular boosters and the network closet belong in the must-run tier from Step 2. 

Step 6 — Organize the Team, Train, and Test

A continuity plan is only as effective as the organization’s ability to execute it under pressure. Ready.gov recommends establishing a business continuity team, developing the plan, then training employees and conducting exercises to validate recovery strategies. 

Build the team around the functions affected by an outage, ensure each department has a designated lead, and designate one individual to coordinate the overall continuity plan and make time-sensitive decisions. 

Training should address two levels of readiness. All employees should understand how they will be notified, where to report, and what their responsibilities are. Designated response teams need hands-on training on critical systems and procedures, including transferring to backup power, executing load-shedding procedures, and connecting a mobile power unit to a building inlet. 

Test readiness in escalating stages: 

  1. Tabletop exercise. Walk through a seven-day outage scenario to identify gaps in decision-making, communications, responsibilities and handoffs. 
  2. Functional test. Operate backup power under an actual facility load—not simply a no-load startup. Batteries and generators that perform successfully during routine checks can still fail under operational demand. 
  3. Full-scale exercise. On a planned date, disconnect utility power and operate the facility according to the continuity plan.

After each exercise, document failures, gaps and corrective actions. Assign owners and deadlines for updating the plan, then retest as needed. Conduct exercises at least annually and whenever significant changes are made to equipment, facilities, processes or staffing. 

Don't Forget the Recovery Phase

Once the lights come back on, focus on the recovery phase. 

Assess and document damage. Inspect electrical rooms, equipment and backup systems before returning them to normal service. For insurance and federal reimbursement, photograph and video the facility now, before any event, and again afterward. Store those records, along with equipment inventories and maintenance logs, in waterproof storage and in an off-site or cloud copy. 

Restore in BIA order. The priorities from Step 1 apply in reverse when power returns. Bring the must-run tier onto stable utility power first, then the flexible tier, then the sheddable loads. Restarting everything at once can trip breakers and damage motors. 

Return to grid power safely. Confirm with the utility that service is stable before transferring. Voltage can fluctuate for hours after restoration, and a second outage during transfer is common. Hybrid systems help here because the battery can hold the load through a brief dip. 

Demobilize temporary power. Disconnect mobile units, refuel and recharge them, inspect cables and connectors, and return them to their staging location ready for the next deployment. Log fuel used and runtime hours. Those numbers will sharpen your sizing and fuel assumptions for the next revision of the plan. 

Power Outage Business Continuity Plan Checklist

Use this list to check your business continuity plan for power outage readiness. 

Longer power outages require more than emergency backup. Organizations need a resilient power strategy built around critical loads, recovery targets and operational needs. 

AGBESS helps organizations prepare with flexible hybrid power solutions. Our complimentary project analysis can size a system to your loads, model potential generator and fuel savings, and identify the right approach for your facility. 

Contact AGBESS Gov Sales at (724) 313-6979 or govsales@agbess.com. 

FAQ

It should include a business impact analysis, a tiered list of critical loads sized in kW, and recovery time and recovery point objectives for each critical function. It also needs a backup power strategy matched to those objectives, communication protocols that work without email, a trained team with a testing schedule, and a recovery procedure for returning to grid power. 

Plan for up to seven days. Major storms regularly leave customers without power for several days, and facilities outside the top utility restoration tier can wait longer. Size fuel storage, battery capacity and your load-shedding sequence so must-run loads stay powered for the full period, including the possibility that fuel deliveries are delayed. 

A generator burns fuel continuously to produce power for as long as it runs. A hybrid power system adds battery storage and a controller and can also take in solar and grid power. The batteries carry most of the load, and the generator runs only to recharge them or to meet peak demand. That means less fuel, less noise, less engine wear and a backup source if the generator fails. 

Through cooperative purchasing. Organizations such as Sourcewell competitively solicit and award contracts on behalf of member agencies, so members can buy from awarded vendors without running their own bid. ZeroBase hybrid power systems are available through AGBESS on Sourcewell contract #062625-ASTG. Membership is free for qualifying government, education and nonprofit entities. 

Share the Post:
Interested in learning more?
schedule a consultation with our team.